TEGAM New Product Acquisition

Key TEGAM / PPM Product Additions include:

AVM-2000 Precision Null Detector/Nanovoltmeter is a  multi-range analog DC Voltmeter/Null Meter with 21 bipolar ranges from 100 nV full scale to 1000 V, with a resolution to 2 nV, and >100 G ohm isolation. The rechargeable battery provides 50 hours of operation, and the AVM-2000 is ideal for Sub PPM Voltage, Resistance and temperature Calibration Transfers.

To download the AVM-2000 datasheet click here.

To visit the TEGAM website for more AVM-2000 details click here.

R1L Series of  MICRO-OHMMETERS & Model R1M MEG-OHMMETER provide a full family of portable, rugged resistance measurement products to meet all application requirements, including:  Bonding testing with 1 micro-Ohm resolution in low cost general application and intrinsically safe models, Ground resistance monitoring with 1 micro-ohm resolution and ranges from 20 to 20,000 ohms full scale and a Gigohmmeter for insulation resistance testing with 6 ranges from 1 Megohms to 200 Gigohms full scale.

To view all TEGAM Micro-ohmmeters click here, and for TEGAM Meg-ohmmeters click here.

To discuss your TEGAM application requirements contact us at [email protected]

Like this article?

Share on facebook
Share on Facebook
Share on twitter
Share on Twitter
Share on linkedin
Share on Linkdin
Share on pinterest
Share on Pinterest
830 Front View
Front View

Functions and Applications

Model 830 (5) valve kit provides the capability for testing all brands of reduced pressure principle, pressure vacuum breaker and double check valve backflow prevention assemblies

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

∆P Range:

0-15 PSID / 0-100 KPA

  • Industry Standard for over 30 years
  • (5) Valve Test Kit
  • Specially Designed for Testing Backflow Prevention Assemblies
  • Soft-Seated Brass Needle Valves (with replaceable valve seats)
  • Test kit is protected with 90 micron filters to minimize plugging with scale, sand, etc.
    Filter elements can be cleaned or replaced
  • Durable Molded Carrying Case with Removable Lid
  • Test Procedures are Laminated in Clear Plastic
  • 5 Year Manufacturer Warranty
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4-1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic.
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1-1/2″ 0-200 PSIG
  • Tubing & Fittings: Brass & Nylon
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded).
  • Bleed Tube, One each / 4′ long clear bleed tube.
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks.
  • Weight, case & gauge combined: 14lbs/6.4 kilos
  • Case: Polyethylene
  • Size: 16″H x 14″W x 8-3/4″D
  • Temperature Limitations: Maximum 150°F/65°C.
  • FREEZING TEMPERATURES MUST BE AVOIDED

Functions and Applications

Model 845-2 (2) valve kit provides the capability for testing all brands of reduced pressure principle, pressure vacuum breaker and double check valve backflow prevention assemblies.

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

∆P Range:

0-15 PSID / 0-100 KPA

  • Over 30 Years of Input from Backflow Technicians
  • (2) Valve Test Kit
  • Specially Designed for Testing Backflow Prevention Assemblies
  • Soft-Seated Brass Needle Valves (with replaceable valve seats)
  • Test kit is protected with 90 micron filters to minimize plugging with scale, sand, etc. Filter elements can be cleaned or replaced
  • Portable / Removable from Case
  • Durable Molded Plastic Carrying Case
  • Improved Case with Storage Compartments for Fittings & Tools
  • Test Procedures are Laminated in Clear Plastic
  • 5 Year Manufacturer Warranty
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4 1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic.
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1 1/2″ 0-200 PSIG
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded).
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks
  • Gauge Weight: 2.9lbs / 1.3kg
  • Case: Durable Molded Plastic
  • Size: 18 1/2″ L x 9″W x 9 3/4″ H
  • Temperature Limitations: Maximum 150°F/65°C
  • FREEZING TEMPERATURES MUST BE AVOIDED

Functions and Applications

Model 845-3 (3) valve kit provides the capability for testing all brands of reduced pressure principle, pressure vacuum breaker and double check valve backflow prevention assemblies.

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

∆P Range:

0-15 PSID / 0-100 KPA

  • Over 30 Years of Input from Backflow Technicians
  • (3) Valve Test Kit
  • Specially Designed for Testing Backflow Prevention Assemblies
  • Soft-Seated Brass Needle Valves (with replaceable valve seats)
  • Test kit is protected with 90 micron filters to minimize plugging with scale, sand, etc. Filter elements can be cleaned or replaced
  • Portable / Removable from Case
  • Durable Molded Plastic Carrying Case
  • Improved Case with Storage Compartments for Fittings & Tools
  • Test Procedures are Laminated in Clear Plastic
  • 5 Year Manufacturer Warranty
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4-1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic.
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1-1/2 0-200 PSIG
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded).
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks
  • Gauge Weight: 3.3lbs / 1.5kg
  • Case: Durable Molded Plastic
  • Size: 18-1/2″L x 9″W x 9-3/4″H
  • Temperature Limitations: Maximum 150°F/65°C
  • FREEZING TEMPERATURES MUST BE AVOIDED

Functions and Applications

Identical to our most popular Model 845-5 except Dial, Hoses and Carrying Case are easily identified for NON-POTABLE Service.

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

845-5-NP® is registered in the U.S. Patent and Trademark Office

∆P Range:

0-15 PSID / 0-100 KPA

  • Easily Identify Gauges & Hoses for NON-POTABLE Service
  • (5) Valve Test Kit
  • Specially Designed for Testing Backflow Prevention Assemblies
  • Soft-Seated Brass Needle Valves (with replaceable valve seats)
  • Test kit is protected with 90 micron filters to minimize plugging with scale, sand, etc. Filter elements can be cleaned or replaced
  • Portable / Removable from Case
  • Durable Molded Plastic Carrying Case
  • Improved Case with Storage Compartments for Fittings & Tools
  • Test Procedures are Laminated in Clear Plastic
  • 1 Year Manufacturer Warranty
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4 1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1 1/2″ 0-200 PSIG
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded)
  • Bleed Tube, One each / 4′ long clear bleed tube.
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks
  • Gauge Weight: 3.6lbs / 1.6kg
  • Case: Durable Molded Plastic
  • Size: 18 1/2″L x 9″W x 9 3/4″H
  • Temperature Limitations: Maximum 150°F/65°C
  • FREEZING TEMPERATURES MUST BE AVOIDED

Functions and Applications

Model 845-5 (5) valve kit provides the capability for testing all brands of reduced pressure principle, pressure vacuum breaker and double check valve backflow prevention assemblies.

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

845-5® is registered in the U.S. Patent and Trademark Office

∆P Range:

0-15 PSID / 0-100 KPA

  • Over 30 Years of Input from Backflow Technicians
  • (5) Valve Test Kit
  • Specially Designed for Testing Backflow Prevention Assemblies
  • Soft-Seated Brass Needle Valves (with replaceable valve seats)
  • Test kit is protected with 90 micron filters to minimize plugging with scale, sand, etc. Filter elements can be cleaned or replaced
  • Portable / Removable from Case
  • Durable Molded Plastic Carrying Case
  • Improved Case with Storage Compartments for Fittings & Tools
  • Test Procedures are Laminated in Clear Plastic
  • 5 Year Manufacturer Warranty
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4 1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1 1/2″ 0-200 PSIG
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded)
  • Bleed Tube, One each / 4′ long clear bleed tube.
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks
  • Gauge Weight: 3.6lbs / 1.6kg
  • Case: Durable Molded Plastic
  • Size: 18 1/2″L x 9″W x 9 3/4″H
  • Temperature Limitations: Maximum 150°F/65°C
  • FREEZING TEMPERATURES MUST BE AVOIDED
Model 835 - 5 Valve

Functions and Applications

Model 835 (5) valve kit provides the capability for testing all brands of reduced pressure principle, pressure vacuum breaker and double check valve backflow prevention assemblies.

It is capable of performing all known test procedures including those recommended by ASSE, AWWA, CSA, FCCC and HR-USC and NEWWA.

∆P Range:

0-15 PSID / 0-100 KPA

  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4-1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic.
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1-1/2″ 0-200 PSIG
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded)
  • Bleed Tube, One each / 4′ long clear bleed tube
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks
  • Gauge Weight: 3.6lbs / 1.6kg
  • Weight, Gauge & Case combined: 11.6lbs / 5.2kg
  • Case: Polyethylene
  • Size: 16″H x 14″W x 8-3/4″D
  • Temperature Limitations: Maximum 150°F/65°C
  • Gauge Type Diaphragm Differential Pressure
  • Dial Size & Range (4-1/2″) 0-15 PSID / 0-100 KPA
  • Differential Pressure Accuracy ± .2 P.S.I.D. (Descending)
  • Working Pressure: 200 PSIG
  • Body Material: Glass Reinforced Engineering Thermoplastic.
  • Wetted Internals: EP Elastomers, Brass and 316 S.S. Metal Parts
  • Line Pressure Gauge: 1-1/2″ 0-200 PSIG
  • Tubing & Fittings: Brass & Nylon
  • Hoses & End Fittings: Buna-N jacket and liner. Schrader 1/4″ brass coupler –
  • Hose Length: Three (3) each / 5′ long (color-coded).
  • Bleed Tube, One each / 4′ long clear bleed tube.
  • Adaptor Fittings: (3) sets of brass fittings provided for hookup to all standard size test cocks.
  • Weight, case & gauge combined: 14lbs/6.4 kilos
  • Case: Polyethylene
  • Size: 16″H x 14″W x 8-3/4″D
  • Temperature Limitations: Maximum 150°F/65°C.
  • FREEZING TEMPERATURES MUST BE AVOIDED